SP2000-H/DILBasedonprobeSP2000H/
取樣探頭 產品詳情

SP2000-H/DIL

Based on probe SP2000H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre-heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.


SP2300-H/DIL

Based on probe SP2300H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre-heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

Material: PTFE, FPM, ceramic

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2300H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.


SP2000-H320/DIL

Based on probe SP2000H/....

Electrically heated up to 320°C

External critical orifice is heated

Including a dilution gas pre-heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.


SP2000-H/DIL-VA

Based on probe SP2000H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre- heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With integrated ball valve at the probe inlet

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. With the integrated ball valve it is possible to shut off the probe from the process for example to change the filter element in case of toxic sample gas.


SP2000-H/DIL-B

Based on probe SP2000H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre- heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With bypass injector to minimize the response time

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.The additional bypass injector minimizes the response time.


SP2000-H320/DIL-B

Based on probe SP2000H/....

Electrically heated up to 320°C

External critical orifice is heated

Including a dilution gas pre- heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With bypass injector to minimize the response time

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.The additional bypass injector minimizes the response time.


SP2000-H/DIL-BR

Based on probe SP2000H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre- heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With bypass injector to minimize the response time and integrated gas recirculation

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.The additional bypass injector minimizes the response time and the integrated gas recirculation allows to remove the sample gas back into the process.

SP2000-H320/DIL-BR

Based on probe SP2000H/....

Electrically heated up to 320°C

External critical orifice is heated

Including a dilution gas pre- heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With bypass injector to minimize the response time and integrated gas recirculation

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.The additional bypass injector minimizes the response time and the integrated gas recirculation allows to remove the sample gas back into the process.

SP2000-H/DIL-VA-B

Based on probe SP2000H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre- heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With integrated ball valve at the probe inlet and bypass injector to minimize the response time

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials.With the integrated ball valve it is possible to shut off the probe from the process for example to change the filter element in case of toxic sample gas and the additional bypass injector minimizes the response time.


SP2000-H/DIL-VA-BV

Based on probe SP2000H/....

Electrically heated up to 180°C

External critical orifice is heated

Including a dilution gas pre-heater

No dew point problems

Dilution rates from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Easy operation and maintenance

With heated hand-operated ball valve at the sample inlet and bypass connection with needle valve in order to minimize the response time

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2000H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. With the integrated ball valve it is possible to shut off the probe from the process for example to change the filter element in case of toxic sample gas and the additional bypass injector with needle valve minimizes the response time.


SP2006-H/DIL-B/2x/F

Based on probe SP2000-H/...

Electrically heated up to 180 °C or 280 °C

NEMA 4, FRP housing

External heated critical orifice with additional safety filter

Including a dilution gas pre-heater

No dew point problems

Dilution ratios from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Changing of dilution and bypass block without any tools within a few minutes

No disconnection of any tubes or hoses for changing of dilution or bypass block

Easy operation and maintenance

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2006H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. The additional bypass injector minimizes the response time.


SP2006-H/DIL-BR/2x/F

Based on probe SP2000-H/...

Electrically heated up to 180 °C or 280 °C

NEMA 4, FRP housing

External heated critical orifice with additional safety filter

Including a dilution gas pre-heater

No dew point problems

Dilution ratios from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Changing of dilution and bypass block without any tools within a few minutes

No disconnection of any tubes or hoses for changing of dilution or bypass block

Easy operation and maintenance

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2006H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. The additional bypass injector minimizes the response time.


SP2006-H/DIL/2x/F

Based on probe SP2000-H/...

Electrically heated up to 180 °C or 280 °C

NEMA 4, FRP housing

External heated critical orifice with additional safety filter

Including a dilution gas pre-heater

No dew point problems

Dilution ratios from 10:1 up to 500:1

With check gas connection

Independent of the process temperature

Changing of dilution and bypass block without any tools within a few minutes

No disconnection of any tubes or hoses for changing of dilution or bypass block

Easy operation and maintenance

Application:

The electrically heated M&C dilution probe is applicable for such processes, where the measuring procedure or the handling of the process gas require the dilution of the sample respectively the component to be measured. Typical applications are the use with toxic gases, the moisture measurement and the emission measurement in flue gases. The M&C dilution probe SP2006H/DIL... is based on the well tested M&C gas sample probe SP2000H. This enables the user to adapt the probe to nearly every application, using for example special filter techniques or special materials. The additional bypass injector minimizes the response time.

熱門產品
產品名稱參考價地區公司名稱更新時間 
熒光定量真菌毒素檢測儀 優云譜 糧食安全快速檢測儀 YP-L02 面議 濰坊市 山東優云譜光電科技有限公司 2025-05-01 在線詢價
艾德克斯ITECH 微功耗量測以及材料研究精密源表 IT2805 200V1.5A20W 面議 深圳市 深圳市賽儀歐電子有限公司 2025-03-04 在線詢價
自動測量圖像尺寸設備 ¥560000 深圳市 深圳市中圖儀器股份有限公司 2025-03-09 在線詢價
羅卓尼克USB接口水活性快速測量探頭 面議 無錫市 無錫徽科特測控技術有限公司 2025-03-10 在線詢價
激光功率測量系統 LPMS 面議 上海倍藍光電科技有限公司 2025-04-08 在線詢價
水分活度測量儀廠商 面議 常州市 常州金壇泰納儀器廠 2025-03-10 在線詢價
免責申明

所展示的信息由會員自行提供,內容的真實性、準確性和合法性由發布會員負責,儀表網對此不承擔任何責任。儀表網不涉及用戶間因交易而產生的法律關系及法律糾紛,糾紛由您自行協商解決

友情提醒 :本網站僅作為用戶尋找交易對象,就貨物和服務的交易進行協商,以及獲取各類與貿易相關的服務信息的平臺。為避免產生購買風險,建議您在購買相關產品前務必確認供應商資質及產品質量。過低的價格、夸張的描述、私人銀行賬戶等都有可能是虛假信息,請采購商謹慎對待,謹防欺詐,對于任何付款行為請您慎重抉擇!如您遇到欺詐等不誠信行為,請您立即與儀表網聯系,如查證屬實,儀表網會對該企業商鋪做注銷處理,但儀表網不對您因此造成的損失承擔責任!

關于我們|網站導航|本站服務|會員服務|網站建設|特色服務|旗下網站|友情鏈接|在線投訴|興旺通|供應信息

儀表網-儀器儀表行業“互聯網+”服務平臺

Copyright ybzhan.cn All Rights Reserved法律顧問:浙江天冊律師事務所 賈熙明律師ICP備案號:浙B2-20100369-24

客服熱線:0571-87756399,87759942加盟熱線:0571-87756399展會合作:0571-87759945客服郵箱:873582202@qq.com 投稿郵箱:ybzhan@qq.com

網站客服:服務咨詢:對外合作:儀表采購群: 儀表技術群:

版權所有©浙江興旺寶明通網絡有限公司


提示

×

*您想獲取產品的資料:

以上可多選,勾選其他,可自行輸入要求

個人信息:

主站蜘蛛池模板: 黑人videovideosex 黑人操日本人视频 | 青青草成人影院 | 日韩欧美综合在线二区三区 | 国产一区二区三区在线观看免费 | 国产精品 日韩 | 中文字幕一区在线播放 | 亚洲一区二区三区四区在线 | 国产三级观看久久 | 精品哟哟哟国产在线观看不卡 | 午夜影院小视频 | 中文字幕视频一区 | 精品国产免费第一区二区 | 成年人网址在线观看 | 久久精品国产欧美日韩99热 | 久久精品最新免费国产成人 | 国产精品久久久久久免费 | 天天干天天干天天天天天天爽 | 精品欧美成人高清视频在线观看 | 亚洲视频中文字幕在线观看 | 久久综合九色欧美综合狠狠 | 国产成人黄网在线免 | 中文字幕免费在线播放 | 我要看一级黄色毛片 | 99热国内精品 | aaaaaaaaa在线观看 | 日本午夜网站 | 国产 日韩 欧美 高清 | 精品久久天干天天天按摩 | 国产精品第三页 | 国产在线视频一区二区三区 | 你懂的中文字幕 | 久久久久成人精品免费播放动漫 | 欧美不卡一区二区三区免 | 欧美做a一级视频免费观看 欧美最猛性xxxxx短视频 | 日本国产一区 | 国产精品成人在线 | 青春草在线免费观看 | 欧美日韩第一页 | 欧美色久 | 人人爱天天做夜夜爽 | 色视频免费网站 |