Coupling network Surge Four unshielded unsymmetrical interconnection lines CWG 1528 ♦ 4 lines 6A, 250 VAC ♦ For surge test line-to-line and line-to-ground coupling
德國施羅德SCHLODER浪涌測試儀
♦ RS 232 Introduction The coupling network can be used to carry out EMC tests to the standards IEC 61000-4-5 (surge). The interference pulses of the surge generator are coupled to the interconnection lines of the tested unit. The coupling paths (line to line or line to earth) can be selected by using the coupling switches. The coupling network can be operated via an RS 232 interface with a personal computer – together with the surge generator CWG 1500 / CWG 500. So the selection of the coupling paths can be
automated. Technical data Nominal voltage AC max. 240 V / 50 Hz Nominal voltage DC max. 120 V Nominal /max. current 4 x 6 A at 40° C ambient temperature Decoupling inductance 4 x 20 mH / 6 A (Serial choke) Coupling capacity 0,5 µF and 40 ohm Max. surge pulse 1,2/50 µs 4400 V High voltage surge input Fischer high voltage jack D105A039 EUT feeding laboratory-banana-jacks EUT connection laboratory-banana-jacks Remote serial, RS 232 Power supply electronic control system IEC-plug 230 V / 50 Hz / 1 A on rear side Additional earth connection jacks on front and rear side Temperature environment 0 - 40 °C Rel. humidity 0 – 60% Cabinet 19" housing, 3 HE Weight app. 14 kg